<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-29 02-56-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 78 dBuV YLEX
Pilot RDS Phase Difference
5.7 kHz 4.2 kHz 76 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 60 kHz 18834 0,6106
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,3 dBr 3,13 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 --:--
RT
-
AF EON
89.8, 91.4, 91.5, 92.3, 92.6, 93.2, 94.0, 95.3, 95.4, 96.0, 97.0, 97.6 MHz 6203
FM Scope Max at: 60 kHz MIN: 11 kHz % above 76 kHz: 0,6106 Acquired: 2025/06/29 2.55.36 Total samples: 18834 Equivalent time: 0:15:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,1 dBr MIN: 1,3 dBr AVE: 3,13 dBr % above 12,2 dBr: 0,0 Last value: 2,9 dBr (2025/06/29 2.55.36) 02.42 02.44 02.46 02.48 02.50 02.52 02.54 0 2 4 Pm [dBr]